Kit Packing C5 Vette
PAC controller ____
Pump w/4 Feet shielded cable ____
4 Feet 7/16 split loom ____
2 long wire ties ____
PAC wiring + DS tape ____
18 inch hose 6 -6 ____
22 inch hose 4 4 ____
32 inch hose -4 4 ____
Methanol Filter ____
90’ 3/8 –6 fitting ____
90’ 3/8 –4 fitting ____
MAP Sensor w/regulator ____
Brass T for MAP ____
4 self tapping w/washers ____
Cap w/vent ____
Tank Plug ____
Bulkhead w/seal ____
90’ ¼-6 fitting ____
Nozzle w/washers + adapter ____
Low level grommet ____
Check valve ____
Nozzle document ____
PAC document ____
MAP document ____
C5 install document ____
Custom Dual nozzle
M10 nozzle ____
1/8 T fitting ____
4 inch 4-4 hose 6 inch 4-4 hose ____
Large check valve ____
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1

Kit Packing C5 Vette PAC controller ____ Pump w/4 Feet shielded cable ____ 4 Feet 7/16 split loom ____ 2 lon

Pagina 2

8) Final At this point you’ve concluded the installation, first thing to do is before putting alcohol/water into the tank, is turn the ignition “on

Pagina 3

Individual results may vary, enjoy the product. 10) Interference On some types of scan-tools it may be possible the PWM signal to drive the pump c

Pagina 4

PAC- Progressive Alcohol Controller Introduction The PAC is a versatile electronic motor controller using pulse width modulation technology

Pagina 5

can be routed from a relay activated by the ignition switch. Black goes to chassis ground. The connections to the injection pump are the Red/Black/Whi

Pagina 6

pump as the signal from the MAP sensor increases. Turning this knob clockwise will increase output voltage multiplication and slightly increase the in

Pagina 7

setting in main controller. Once this is done, monitoring engine knock, race car…. If knock retard is encountered, ascertain if the knock is occurri

Pagina 9

Alky Pump install Important notes… Do Not Mount pump with head facing upwards as this will allow water to collect inside sleeve and ruin motor. Pleas

Pagina 10

C5 Corvette installation instructions 1) The tank modification The windshield washer tank will need to be modified to deliver the fluid to th

Pagina 11

2) Pump mounting Before mounting the pump, install the brass 90 degree fitting on the inlet of the pump, use the larger of the two fittings provided

Pagina 12

3) Nozzle The nozzle will be placed before throttle body. Install head of nozzle in the upper portion of the air bridge 2 o’clock position on Mag

Pagina 13 - Setup and Use

the MAP sensor. At this point remove the lower panel under the dash, and the panel that goes under the steering column. Drill holes and run LED wir

Pagina 14 - Tuning suggestions

2)Razor blade 3)Heat gun or lighter Step 1 Strip insulation from end of pump cable and separate wires. Note there are three wires. Red, Black, ba

Pagina 15

Step 3 Apply heat to the heat-shrink. Step4 Slide large heat-shrink over entire connections Step 5 In the event more than one wire will be at

Pagina 16

Mount PAC controller in aluminum frame, it will need to be loosened to fit in place. Reinstall frame. Then ZIP tie the controller in place through